Test Cabin A60 Zone 1 Specifications
- DNV 2.7.1/ 2.7.2 Zone 1 Hazardous area with A60 fire rated Lab unit designed for positive pressurisation for Zone 1 hazardous area with A60 fire rating Reference codes and standards applied IEC79-13 1982, AWS D1.1, DNV-CN 2.7.1 & 2.7.2
- Unit comes with below equipment: A60 Thermal insulation A60 Main door A60 Escape hatch B15 Air lock door w/view glass 5kVA transformer
- Input: 380/440/460/480V with selector switch
- Output: 110/220V, 50/60 Hz 50 metres of power cable for rig supply Exe junction box c/w terminal blocks for supply connection (PJB) Exe junction box c/w terminal blocks for sensor cable connection (SJB) MCT frames, Cable trays, Earth bosses Exd fluorescent lamps & light switch for workshop & recessed area Small power distribution board IP rated fluorescent lamps for laboratory section Ex proof emergency battery pack lighting Emergency shutdown control switch Shut down dampers Smoke detectors Hydrocarbon gas detector Pressure switch & gauge Loss of pressure alarm Ex proof air blower for pressurization c/w fire retardant flexible hose Flame proof split air conditioning system Wall mounted & standard metal cabinets Certified lifting slings
- Dimensions: 6058mm x 2438mm x 2700mm
- Approx Weight: 10000 kg (Tare: 8000 kg, Payload: 2000 kg)